Waste Processing
Clark Environmental owns and operates a FDEP permitted waste solidification facility processing non-hazardous solids, sludge, liquids, tars and gels in both drum and bulk quantities. Depending on the contaminates of the materials, it will either be processed through our Thermal Treatment Facility, disposed at an approved FDEP subtitle D landfill, or processed through a FDEP permitted wastewater treatment facility.
Clark Environmental also handles spill cleanup absorbents (booms, pads, filters etc.) contaminated PPE, along with off-specification and unused product.Clark Environmental accepts difficult materials such as tank bottom sludges because sludge is our specialty! Additionally, we handle empty drums and containers for recycling.
Certificates of Acceptance, Treatment and Disposal are also available on request.
Request a Quote
Request a QuoteTesting Requirements
MATERIAL ACCEPTANCE CRITERIA
|
Waste Type |
Minimum Analyses |
EPA Test |
|
Petroleum Contaminated Soil |
Virgin Diesel: |
None |
|
Gasoline: TCLP Benzene |
1311 |
|
|
Used Oil: TCLP Volatiles, TCLP Metals |
1311 |
|
|
Petroleum Contaminated Soil from Vehicle Accident and/or Spill |
Virgin Diesel: |
None |
|
Gasoline: TCLP Benzene |
1311 |
|
|
Used Oil: TCLP Benzene, Arsenic, Cadmium, Chromium, Lead |
1311 |
|
|
Petroleum Contaminated Soil for Thermal Treatment |
In accordance with 62-713 |
|
|
Non-Virgin Processed or Waste Petroleum Contaminated Water (not regulated as PCW) |
Analysis Determined on Case by case |
|
|
Petroleum Tank Bottom Sludges |
Diesel & Fuel Oils: Tank Certification |
|
|
|
Gasoline: Flashpoint, TCLP Benzene, TCLP Lead |
1010, 1311 |
|
|
Used Oil: Flashpoint, TCLP Volatiles, TCLP Metals |
1010, 1311 |
|
Petroleum Contaminated Water Virgin Product (not regulated as PCW |
MSDS |
|
|
Petroleum Contaminated Sorbent Materials (Pads, Booms, etc.) |
Virgin Diesel: |
None |
|
|
Gasoline: TCLP Benzene |
1311 |
|
|
Used Oil: TCLP Benzene, Arsenic, Cadmium, Chromium, Lead |
1311 |
|
Liquid, Sludges, Sediments from Wash Sumps / oil-water seperators |
TCLP Benzene, Arsenic, Cadmium, Chromium, Lead |
1311 |
|
Oil/Water Separator Sludges (Other than car/truck washes) |
Analysis Determined on Case by Case |
|
|
Soils & liquids, contaminated by virgin, non-haz materials, from accident spills |
MSDS |
|
|
IDW from sites contaminated by dry cleaning solvents |
Volatile Organics |
601/602 |
|
IDW from non-petroleum, non-dry cleaning sites |
Analysis Determined on Case by Case |
|
|
Any Non-RCRA Regulated Virgin Chemical not listed above |
MSDS, Additional Analysis Determined on Case by Case |
|
|
Antifreeze |
TCLP Benzene, Lead, PCE, TCE |
8240, 7421 |
|
Latex paint and paint sludges / inks and ink sludges |
MSDS |
|
|
Empty containers |
MSDS |
|
|
Dry cell batteries, non-hazardous |
MSDS |
|
|
Industrial solid wastes from non-petroleum, non-dry cleaning sites |
Analysis Determined on Case by Case |
|
Permits
|
Permit |
Permit Number |
Iss. Date |
Exp. Date |
|
Waste Processing Facility Permit |
38627-007-SO/30 |
6/18/2009 |
6/18/2014 |
|
CERCLA Approval |
30627-001-80 |
8/15/2000 |
|
|
Water Quality Monitoring Permit |
215408-002-SO(GW) |
10/28/2008 |
10/28/2013 |
|
Environmental Resource Permit |
53-0215740-001 |
2/25/2004 |
|
|
Financial Assurance Approval |
WACS00051555 |
4/16/2011 |
|
|
Closing Costs |
$206,870.32 |
||
|
Long Term Care |
$24,705.41 |